GENERAL INFORMATION

In the present manual you will find all necessary instructions with regard to the installation, operation and

maintenance of the product.

 

The company is active in the Solar Energy with high-tech equipment, ultra-modern facilities and certified products 

of high quality. Our experience and know-how support our co operations, before and after sales, both in Europe and 

internationally.

Nowadays, the necessity for production and saving of energy without at the same time polluting the environment has 

become common knowledge. The planetʼs conventional energy resources are diminishing to a threatening level as 

our societyʼs energy requirements are increasing, generating pollutants that affect the climateʼs balance. Renewable 

energy sources promise a solution to the energy problem as well as to pollution. Gradually, the international legislation 

is changing and encouraging - or even imposing - the use of alternative energy products, with the aim to satisfy 

energy requirements without endangering the environment.

DOMESTIC HOT WATER CONSUMPTION

Statistically, it is estimated that the mean family consumption is 35 to 50 litres daily per person. If we add the 

consumption of a washing machine and a dishwasher, when these are connected to the solar water storage tank, then 

each requires 20 litres per day (per wash). Thus, a family of four, for example, with a mean hot water consumption 

of 40 litres per person, needs an 160 litres solar water heater. If household appliances connected to the solar water 

heater are added, then the demand increases by at least 40 litres daily. In order to take full advantage of the solar 

water heater, maximum use of hot water should be made during daytime, so that the system can continuously 

produce hot water during the daylight hours, maintaining thus its maximum efficiency. 

SOLAR WATER HEATING

The collecting surface absorbs solar energy and heats the liquid (water or antifreeze mixture) that circulates in the 

water element. This liquid is directed to the water storage tank where it heats the water. The factors that affect the 

temperature of the water supplied by a solar system are many and their values vary according to the season, the time 

of day and the location. Keeping in mind that the solar system is a system that is exposed to the weather conditions, 

basic parameters affecting its performance are the mains water temperature, the available solar energy and the 

ambient temperature. The mains water does not have a constant temperature throughout the year, being much colder 

in winter compared to summer. Considering 45°C as a satisfactory temperature for the domestic hot water (in order 

to fulfil the needs of a home) and based on statistic values, in winter the temperature of the mains water has to be 

increased by approximately 35°C, whereas during the summer the increase is 20°C.

Similarly, the available solar energy does not remain the same throughout the year, being much less in the winter 

months than in the summer months. During periods of reduced sunlight and low ambient temperatures, the solar 

water storage tank assures the preheating of the water and can be assisted by an optional electrical heating element. 

As far as night-time temperature losses are concerned, these are limited as much as possible by the solar system’s 

powerful thermal insulation. They are nevertheless affected by ambient temperatures, which vary depending on the 

location and the weather.

Summary of Contents for V-04212

Page 1: ...Forced Circulation Boilers Installation maintenance use instructions TECHNICAL MANUAL...

Page 2: ......

Page 3: ...TION RULES 8 INSTALLATION POSITION 9 GENERAL PREVENTION MEASURES 10 INSTRUCTIONS FOR THE INTERCONNECTION OF COLLECTORS IN SOLAR FIELDS 10 RECOMMENDATIONS ON HEAT TRANSFER MEANS AND SAFETY AND PROTECTI...

Page 4: ...ses by at least 40 litres daily In order to take full advantage of the solar water heater maximum use of hot water should be made during daytime so that the system can continuously produce hot water d...

Page 5: ...every region and the system s size while at the same time the carbon dioxide emissions are reduced Central solar systems are made of excellent materials according to international specifications and h...

Page 6: ...element rated according to the local regulations of the country of destination Automatically regulated thermostat with bipolar protection and auxiliary fuse The Electrical components for over 300lt ca...

Page 7: ...1 f G Flange for servicing W Upper flange with a magnesium anode MODEL 300 160 Total capacity EN 12897 l 300 160 Actual capacity EN 12897 l 291 156 Net Weight kg 92 54 Insulation mm 50 50 Heat exchang...

Page 8: ...d that insurance for the solar collector is issued GENERAL INSTALLATION RULES ATTENTION Installation must be in compliance with local national rules concerning water and electrical installations plumb...

Page 9: ...lity that may be the result of an inappropriate installation or incorrect use of components used for the solar water heater installation INSTALLATION POSITION The installation is only allowed on roofs...

Page 10: ...alized companies and trained personnel y y Works in electrical installations or conductors have to be executed by trained specialized electro technicians only Labour uniforms y y Have protection glass...

Page 11: ...UM OPERATING PRESSURE PRESSURE DROP MAXIMUM AND MINIMUM INCLINATION ANGLE The maximum operating pressure taking into account the increase in pressure due to the water s expansion must not exceed 400 k...

Page 12: ...rovided with communication keys and a screen on which the parameters and messages are displayed Systems can also be provided with y y Antifrost protection system for the closed loop y y Closed loop ov...

Page 13: ...which we have connected the safety valve 20 the boiler expansion tank 21 the pressure regulator and the non return valve to the position E 6 Connect the hot water consumption 26 to the position C A th...

Page 14: ...rding to the company s instructions In case of any failure condition a specialized technician should be called in A basic periodic maintenance will assure the long life and high efficiency of the sola...

Page 15: ...d UV protection on the thermal insulation Is the piping properly insulated Has the installment on the roof been done according to the local regulations HYDRAULIC CONNECTIONS Are there any leaks in the...

Page 16: ...V2 03 14 www orkli es...

Reviews: