The company preserves the right to change all specifications of the products and their accessories without prior notice

FORCED CIRCULATION SYSTEMS OPERATION AND INSTALLATION

Forced circulation central solar systems are used for the production of hot water for domestic use. They are an 

ecological proposal and an efficient energy solution, combining high efficiency, autonomy, design, ease of installation 

and savings, as the cost for the consumption of conventional energy sources is significantly reduced. 

OPERATION: 

The system’s automations constantly monitor the temperature difference between the collectors and 

the boiler and give the relevant orders to assure the constant supply of hot water according to the circuit settings.

The differential thermostat is electronically programmed to control the differential temperature and is provided with 

communication keys and a screen on which the parameters and messages are displayed.

Systems can also be provided with:

 

y

Antifrost protection system for the closed loop.

 

y

Closed loop overheating protection system.

When the collector temperature exceeds the boiler temperature by 6-10°C, the solar system’s circulation pump is 

activated (start differential temperature). The circulation pump will stop when the temperature difference is reduced 

to 3-4°C (Hysterisis).

COLLECTORS

 

1. Collectors

2. Air bleeder

3. Thermometer*

4. Regulation valve*

5. Expansion tank

6. Brake valve

7. Evacuation valve

HYDRAULIC UNIT

10. Safety valve

11. Non return valve

12. Circulation pump

13. Collectors sensor

14. Collectors heat

exchanger sensor

HOT WATER CIRCUIT

20. Safety valve

21. Expansion tank

22. Mains water

23. Recirculation

24. Circulation pump

25. Recirculation sensor

26. Hot water for domestic use

27. Pressure regulator

28. Non return valve

29. Recirculation non return valve

BURNER CIRCUIT

30. Circulation pump

31. Burner heat exchanger

circulation pump

Summary of Contents for V-04212

Page 1: ...Forced Circulation Boilers Installation maintenance use instructions TECHNICAL MANUAL...

Page 2: ......

Page 3: ...TION RULES 8 INSTALLATION POSITION 9 GENERAL PREVENTION MEASURES 10 INSTRUCTIONS FOR THE INTERCONNECTION OF COLLECTORS IN SOLAR FIELDS 10 RECOMMENDATIONS ON HEAT TRANSFER MEANS AND SAFETY AND PROTECTI...

Page 4: ...ses by at least 40 litres daily In order to take full advantage of the solar water heater maximum use of hot water should be made during daytime so that the system can continuously produce hot water d...

Page 5: ...every region and the system s size while at the same time the carbon dioxide emissions are reduced Central solar systems are made of excellent materials according to international specifications and h...

Page 6: ...element rated according to the local regulations of the country of destination Automatically regulated thermostat with bipolar protection and auxiliary fuse The Electrical components for over 300lt ca...

Page 7: ...1 f G Flange for servicing W Upper flange with a magnesium anode MODEL 300 160 Total capacity EN 12897 l 300 160 Actual capacity EN 12897 l 291 156 Net Weight kg 92 54 Insulation mm 50 50 Heat exchang...

Page 8: ...d that insurance for the solar collector is issued GENERAL INSTALLATION RULES ATTENTION Installation must be in compliance with local national rules concerning water and electrical installations plumb...

Page 9: ...lity that may be the result of an inappropriate installation or incorrect use of components used for the solar water heater installation INSTALLATION POSITION The installation is only allowed on roofs...

Page 10: ...alized companies and trained personnel y y Works in electrical installations or conductors have to be executed by trained specialized electro technicians only Labour uniforms y y Have protection glass...

Page 11: ...UM OPERATING PRESSURE PRESSURE DROP MAXIMUM AND MINIMUM INCLINATION ANGLE The maximum operating pressure taking into account the increase in pressure due to the water s expansion must not exceed 400 k...

Page 12: ...rovided with communication keys and a screen on which the parameters and messages are displayed Systems can also be provided with y y Antifrost protection system for the closed loop y y Closed loop ov...

Page 13: ...which we have connected the safety valve 20 the boiler expansion tank 21 the pressure regulator and the non return valve to the position E 6 Connect the hot water consumption 26 to the position C A th...

Page 14: ...rding to the company s instructions In case of any failure condition a specialized technician should be called in A basic periodic maintenance will assure the long life and high efficiency of the sola...

Page 15: ...d UV protection on the thermal insulation Is the piping properly insulated Has the installment on the roof been done according to the local regulations HYDRAULIC CONNECTIONS Are there any leaks in the...

Page 16: ...V2 03 14 www orkli es...

Reviews: