7
The company preserves the right to change all specifications of the products and their accessories without prior notice
FORCED CIRCULATION BOILERS
Model
A
B
C
D
E
F
G
H
I
J
K
L
M
N
P
Q
R
D ext. D int.
S
160
671
360
785
284
200
1007
314
74
785
600
500
9
300
804
653
1207
288
200
1420
314
206
1207
846
650
550
12
S:
Spiral (No of turns)
*units in mm
160, 300 (lt)
H
Recirculation
¾″ f
B
Thermo pocket 1
½″ f
J
Electric heating element
1 ½″ f
U
Thermometer
½″ f
I
Thermo pocket 2
½″ f
E
Inlet cold water
1″ f
A
Inlet heat exchanger
1″ f
D
Outlet heat exchanger
1″ f
C
Outlet hot water
1″ f
G
Flange for servicing
W
Upper flange with a magnesium anode
MODEL
300
160
Total capacity (EN 12897)
l
300
160
Actual capacity (EN 12897)
l
291
156
Net Weight
kg
92
54
Insulation
mm
50
50
Heat exchanger surface (S1 - lower HE)
m
2
1.45
0.96
Heat exchanger content (S1)
l
8.8
5.8
Exchanged power of HE S1 in continuous mood
kW
70-90°C
52
39
60-80°C
39
31
50-70°C
29
17
50-60°C
24
9
"Max. flow rate of DHW with ΔT35°C
(S1); continuous mood"
l/min
70-90°C
37
28
60-80°C
28
22
50-70°C
21
12
50-60°C
34
13
Quantity of hot water MIX 45°C (S1)
l
330
190
Heat loss (ΔT45K)
kW/24h
2.1
1.6
Max. working temperature
°C
95
95
Max. working temperature coil HE
°C
110
110
Max. pressure of water tank
MPa
0.8
0.8
Max. pressure of coil heat exchanger
MPa
0.6
0.6
D Ext.
W
F
I
J
U
G
D Int.
C
A
B
H
E
D