17(22)
8. Technical specification
Printed circuit board
Net ports:
5 OriLink® ports
(A)
for data
communication, 2 without
+24VDC.
Discrete level inputs: 4
(F),
for one or two levels.
Switch or active signal max 50
V. Supports reorder and stop
set-up for both fresh and waste
oil.
Control outputs:
4
(F)
for solenoid valve 24
VDC max 1,25 A. Closes after
about 30 s when short
circuited, this is logged in the
database.
Analogue level inputs: 4
(G)
4 - 20mA, 24VDC with
10-bit A/D-converters.
Other:
RISC-based microprocessor
EEPROM, 64 KB.
Connector
(E)
for 3-pos key switch. Connector
(C)
for 24 VDC power supply.
SetupLock jumper
(H)
, not used.
Fuses:
T6.3A
(D)
and F1.6A
(B)
Max current:
500 mA + 4x1.25 A for solenoid valves.
Casing
Power supply:
Primary 230VAC/50Hz/2A or 110VAC/60Hz/3A set by a switch.
Short circuit protected
Casing:
Strong black powder painted steel box
Outer measures:
345 x 265 x 65 mm.
Fitting:
4 x ø5mm
CC = 290 x 210 mm
Weight:
3,9 kg.
Environment
Use:
Indoors.
Temperature 0 - +55°C
Humidity 90-95%, not condensing
Transport:
Temperature –40 - +70°C
Humidity 90-95%, not condensing
Storage:
Temperature –40 - +70°C
Humidity 90-95%, not condensing