Orion OriLink 23430 Manual Download Page 6

 

6(22) 

Reel:SETUP     ‡ 
EXIT STOP CE ENT 
 
PASS:_         

 

Enter Password 
 
Addr:8???_     

 

Address[CODE] 
 
TCM:           

 

TCM MainMenu 

TCM:           ‡ 
TCM MainMenu 
 
Address:8XXX   ‡ 
Ange Adress 8??? 
 
Address:8XXX   ‡ 

Set Address 8??? 

4.  Configuration 

An 

OriLink

®

 configuration sheet 

should

 always be filled or altered during the configuration. 

 

NOTE!  To obtain technical support a copy of the configuration sheet for the complete installation must be 

sent to Alentec & Orion AB at 

 

Alentec & Orion AB 
TECHNICAL SUPPORT 
Grustagsvägen 4 
SE-138 40  ÄLTA 
SWEDEN 
 
or 
 
[email protected]

4.1.  Check before configuration 

Check that the TSM is working and communicating with the system according to the OriLink

®

 Manual

 

chapter

 

Testing modules

NOTE! 

Do not forget to check and adjust the termination and BIAS according to OriLink® Manual. 

4.2.  Addressing the TSM 

A new module has a default address when delivered such as MPDM 1000, PM 2000, KP 3000, LED 4000, TSM 
8000 and so on. To set an address for a new TSM or a TSM with unknown address press and hold its RESET button 
for 5 seconds to set a temporary address. Immediately enter set-up mode from a KP and type 0 and then ENTER to 
get to the Main menu of the TSM, see below.  

NOTE! 

Only one new module can be installed at a time. If you press the RESET-button on several 
terminals simultaneously or in a sequence, only the most recently pressed will be active.  

TIP! 

Follow preferably”Recommendation for setting new addresses” when setting addresses. 

4.3.  Set-Up mode 

Type the word 

”SETUP”

 on a KeyPad and press 

ENTER

.  

Type the 

password

 and press 

ENTER

Type the address

 for the TSM that is to be configured and press 

ENTER

 to access 

its main menu. It is possible to add the 4-digit menu code to go directly to the 
desired menu. 

 

Scroll

 through the TSM sub menus by pressing 

 or 

. When the desired menu is 

shown press ENTER etc. On display it shows TCM because the TSM and TSM 
share the same software. 

4.4.  Change address 

[TCM//Address]

 

Enter menu 

[TCM//Address] 

by pressing 

ENTER

 

Press 

ENTER

 to get the cursor. 

 

Type in the 

desired address

 and acknowledge by pressing 

ENTER

. When the 

cursor disappears it is finished. 

 

Press 

EXIT

 two times to leave Set-Up mode. 

 

NOTE!  If two or more TSM’s have the same address the system will fail. The TSM’s has to be re-addressed. 

Hint! 

Follow preferably ”Recommendation for setting addresses” when setting addresses. 

Summary of Contents for OriLink 23430

Page 1: ...Monitoring System Tank Surveillance Module 23430 Covers TSM from serial number 12 020000 with indicator led board and overlay with main board 203 02 91 A with chip version 2 00 00 or later In most pa...

Page 2: ...1 5 5 1 Set tank capacity 11 5 5 2 Set the tank reorder volume level 11 5 5 1 Set the tank stop volume level 11 5 5 2 Set tank bottom area 12 5 5 3 To configure a TSM port for a tank that does not hav...

Page 3: ...using the four 5 mm holes in the bottom corners of the box If a PCB is used it is important that a power supply with enough performance is used 24VBC 5A 3 Electric installation 3 1 The main module The...

Page 4: ...rt is connected to common of the level sensor 24V of a TSM port is connected to one of the terminals of a solenoid valve and Sol is connected to the other TIP If a TSM is used for a tank containing fl...

Page 5: ...of the module 3 3 Lid indicator board 203 03 03 By the indicator board mounted in the lid of the module the status of the discrete level sensors and the pump control can be seen from the outside The i...

Page 6: ...set up mode from a KP and type 0 and then ENTER to get to the Main menu of the TSM see below NOTE Only one new module can be installed at a time If you press the RESET button on several terminals simu...

Page 7: ...he main menu Enter menu TSM PortX by scrolling with or At PortX press ENTER Press ENTER to get the cursor Check the number of the tank that is connected to portX type that number in and press ENTER to...

Page 8: ...justing is used to obtain 0 volume when the tank is empty If the sensor 23 417 is used a normal value is 0 080 The sign is typed on the keypad by first pressing down arrow yellow two times followed by...

Page 9: ...ng to 20 mA If a pressure sensor is used the value should be in bar For sensor part number 23 417 the value should be as default 0 400 Enter menu TCM PortX by scrolling with or At PortX press ENTER Sc...

Page 10: ...art number The fluid part number set in the TSM makes it possible to show the fluid part number in the info box for the graphic representation of the analogue sensor It should be set to the same value...

Page 11: ...k reorder volume level The tank reorder volume set in the TSM is used to create a true graphic representation of the analogue sensor status and start auto warning if that is enabled It should be set t...

Page 12: ...ed in the TSM Enter menu TCM PortX by scrolling with or At PortX press ENTER Scroll to SFS using or Press ENTER to get the cursor Type the sensor full scale value and press ENTER to acknowledge When t...

Page 13: ...g or Press ENTER to get the cursor Type the LED address and press ENTER to acknowledge When the cursor disappears it is finished Press EXIT two times to leave Set Up mode 5 6 2 Set LED update interval...

Page 14: ...and redundancy The system must be told what hardware there is and how to use it properly This is done through the Tank Type Tank type is set by a string of 0 and 1 were the first position sets if it...

Page 15: ...15 22 6 Menu tree...

Page 16: ...the port number Change Offset 0X03 Where X is the port number Change Calibration 0X04 Where X is the port number Change Density of fluid 0X05 Where X is the port number Change Max volume of tank 0X06...

Page 17: ...A D converters Other RISC based microprocessor EEPROM 64 KB Connector E for 3 pos key switch Connector C for 24 VDC power supply SetupLock jumper H not used Fuses T6 3A D and F1 6A B Max current 500...

Page 18: ...e point is open and the sensor works properly the following connection should be made The TSM port should be set to control the appropriate PC tank in relation to the physical tank Correct TankType TS...

Page 19: ...the tank module if the liquid is classed as flammable For this purpose the EX barrier 23178 and a special EX approved cable 23164 can be used The EX barrier the solenoid valve that controls the air t...

Page 20: ...for tanks with a height of 1 5 meters Max height depends on density of fluid The measuring resolution for a TSM with a 23 417 sensor is 4 mm for water and about 4 5 mm for mineral oil Connect the red...

Page 21: ...ld be set using with WinDB Manager MASK TankType 1 12 EX barrier 23 188 for analogue sensors An EX barrier is needed between the level sensor and the tank module if the liquid is classed as flammable...

Page 22: ...In a small system or at limited space it is possible to mount an additional module PCB in a TSM In this example a MPDM board is added To do this the TSM PCB has to be moved and turned one quarter of...

Reviews: