2
Precautions For Safety
Precautions for Use (Danger / Warning)
Danger
Indicates an imminently hazardous situation that, if the product is misused, may bring about death or
serious injury to the operator.
Keep flammable or explosive gas out.
Keep the pump from inhaling flammable or explosive gases. Do not use the unit in
the place where flammable or explosive gas exists.
It may cause explosion or
fire.
Warning
Indicates a potentially hazardous situation that, if the product is misused, may bring about death or
serious injury to the operator.
Do not block the exhaust piping. (B type and V
・
B type)
Do not operate the pump while the pressure controller is totally closed or the exhaust
piping is blocked. Blocking the exhaust air may increase the pressure and
temperature in exhaust piping,
and result in injury and malfunction due to burst
of the piping and pump parts
.
Do not wash filter element with organic solvents.
When cleaning the filter element, do not use organic solvents such as thinner,
alcohol, benzine, gasoline, and kerosene.
It may result in explosion or fire.
Do not remove the cover during operation.
Do not operate this product while the main cover is removed. Otherwise, your
hand(s) may be cut off or be seriously hurt because the cooling fan and the coupling
rotate at high speeds.
Prevent the power cord from any damage.
Do not damage, bend, pull, or bind the power cord. Do not place heavy object on it
or let it get caught or pinched.
It may damage the cord, and may cause electric
shock or fire.
Keep this product away from water.
Do not pour water over the pump and the motor, and do not use water for cleaning
this product. Also, do not use this product where it may touch water or other liquid.
It may cause electric shock or fire.
Be alert to electric shock.
Do not touch electrical parts such as power plug with wet hands. Also, do not
operate switch with wet hands.
It may cause electric shock.
Never fail to put the terminal box cover on.
In the case of a motor with the terminal box, do not operate it with the terminal box
cover removed. It may cause electric shock.
Do not modify the product.
Do not modify the product.
It may cause abnormal operation and may result in injury, electric shock or
fire.
Be sure to ground this product.
Be sure to ground the product with the screw for grounding inside the terminal box or
at the lower part of the frame of the motor.
Failure to do so may cause electric shock.
Summary of Contents for KRF110
Page 28: ...26 Dimensional Outline Drawing KRF70 V 01 04 KRF70 VH 01 04 unit mm...
Page 29: ...27 Dimensional Outline Drawing KRF70 B 01 04 KRF70 BH 01 04 unit mm...
Page 30: ...28 Dimensional Outline Drawing KRF70 VB 01 04 KRF70 VBH 01 04 unit mm...
Page 31: ...29 Dimensional Outline Drawing KRF110 V 01 04 unit mm...
Page 32: ...30 Dimensional Outline Drawing KRF110 B 01 04 unit mm...
Page 33: ...31 Dimensional Outline Drawing KRF110 VB 01 04 unit mm...
Page 34: ...37 memo...
Page 35: ...37 memo...
Page 36: ...K No 0322 12 2 1 C DG TY...