40
Chapter 8: Error Messages and Troubleshooting
The table shows information regarding the various error and messages that may appear on the weld-
er.
ER.N°
MESSAGE
CAUSE
REMEDY
01
Error Simmer
The laser lamp is not switching
on.
A. Check the fuse.
B. Contact
Sunstone / Orion Welders
02
Not Working
Refrigerating Liquid
(Error 02 Test Flux H20)
The refrigerating liquid is not
flowing inside the cooling pipes.
A. The pump is not working.
B. The water is dirty and needs
to be changed.
A. Make sure there is water in the machine,
and that the water level is full. This might
be a good opportunity to change the
water.
B. Before turning the key switch, remove
the red plug on the back of the unit and
push the Joystick down for 5-6 seconds to
force start the water pump and clear any
air in the system. This process may need
to be repeated 2-3 times.
C. Contact Sunstone / Orion Welders.
03
Refrigerating Liquid High
Temperature
The refrigerating liquid has
reached the temperature mark
of 55°C. Possible causes:
A. High work cycle of the ma-
chines.
B. Insufficient liquid inside the
tank.
C. Faulty or not working cooling
fans.
D. Too much dust or dirt on the
heat pump.
A. With the machine turned on, wait 15 min
until the error disappears.
B. Make sure there is water in the machine.
Add water if needed.
C. Make sure the fans are working. If not,
contact Sunstone Engineering.
D. Blow some compressed air into the
machine to try and remove any dust or dirt
that may have settled inside. Do not, how-
ever, open the case without first contact-
ing Sunstone Engineering.
Summary of Contents for Combo 200
Page 1: ...Orion Laser Welder User Manual Orion Combo 200 ...
Page 4: ...4 ...
Page 7: ...7 ...
Page 52: ...52 ...