13
WIRELESS AUTODIAL
HOME ALARM SYSTEM
AM2000
IMPORTANT –
WHEN THE ZONE SETTING
IS CHANGED, THE SENSOR MUST RE-PAIR
WITH AM2000 CONTROL PANEL.
HOME MODE
ZONE
NORMAL
ZONE
SINGLE DELAY
ZONE
TAMPER
SWITCH
ZONE SETUP
LED ON/OFF
SENSOR
HOME MODE ZONE
– when home mode
button is pressed on AM2000 control panel
or the remote control, it will not trigger the
alarm, and therefore occupants can move
freely inside the room. Meanwhile other zone
setting will remain armed.
NORMAL ZONE
– when AM2000 is armed,
if intruder detected, it will trigger alarm
immediately.
SINGLE DELAY ZONE
– when AM2000 is
armed, if intruder detected, it will trigger alarm
after 30 seconds time delay in default settings.
NOTE:
AM2010 PIR motion sensor is set to
“HOME MODE ZONE” by default.
Open the case with a screw driver and remove
the battery insulation strip to power on the sensor.
Once the sensor is powered on, it will start
self testing for one minute.
TESTING MODE:
After self testing, press
the test button on the rear of the sensor, the
sensor enters into testing mode, and detects
once every 10 seconds, walk within the
detection range, from left to right or right to
left and monitor the LED indicator to ensure
the detector is working.
Adjust the sensor angle accordingly to achieve
best detection effect. After 3 minutes, the LED
flashes twice, and the sensor enters working
mode.
WORKING MODE:
in working mode, if the
sensor is triggered more than twice within
3 minutes, it will enter standby mode to save
power. After no movement within next 3 minutes,
the sensor goes back to the working mode.
›
Pairing with AM2000 control panel
Key in the password and press the connect
key on AM2000 control panel, and then press
the test button twice on the back of the sensor
unit. When one beep sound from the AM2000
control panel is heard, they are paired.
To check if they are connected successfully,
arm the AM2000 control panel, trigger the
sensor by walking within the detection range
after exit delay time; if there is an alarm, the
connection is successful.
›
LED indication
FLASH CONTINUOUSLY
–
under self testing mode.
FLASH ONCE
– intruder detected.
FLASH TWICE
– self testing mode completed,
enter to working mode.
FLASH ONCE PER 3 SECONDS
– low battery
indication, please change batteries immediately,
user will get alert SMS for low battery if the PIR
motion sensor is connected to AM2000 control
panel with GSM enabled.
4.4
OPERATION