TES-3080-M12(-BP2) User Manual
ORing Industrial Networking Corp
62
5.8.2 Trap Setting
SNMP traps are event reports sent to a list of managers configured to receive event
notifications when an error occurs. SNMP traps
provide the value of one or more instances
of management information. A trap manager is a management station that receives traps. If
no trap manager is defined, no traps will be issued. You can create a trap manager by entering
the IP address of the station and a community string.
Label
Description
Server IP
The IP address of the server to receive traps
Community
The community string for authentication
Trap Version
The trap version. V1 and V2c are supported.
Add
Click to add the trap sever to the trap server profile.
Trap Server Profile
Shows a list of trap servers, including their community strings and
trap versions.
Remove
Click to remove a trap server from the profile
5.8.3 SNMPV3
Unlike SNMP v1 and v2 which uses community strings for authentication, SNMP v3 uses
username/password authentication, along with an encryption key. Therefore, SNMPv3
provides greater security features for authentication, privacy, and access control. The switch
supports SNMP v3 which can be configured in the following page.