Label
Description
Port No.
The number of port you want to configure
Priority (0-240)
Decide which port should be blocked by priority in the LAN. The
valid value is between 0 and 240, and must be a multiple of 16.
Path Cost
(1-200000000)
The path cost incurred by the port. The path cost is used when
establishing an active topology for the network. Lower path cost
ports are chosen as forwarding ports in favor of higher path cost
ports. The range of valid values is 1 to 200000000.
Admin P2P
Configures whether the port connects to a point-to-point LAN
rather than a shared medium. This can be configured
automatically or set to true or false manually. True means P2P
enabling. False means P2P disabling. Transiting to forwarding
state is faster for point-to-point LANs than for shared media.
Admin Edge
Specify whether this port is an edge port or a nonedge port. An
edge port is not connected to any other bridge. Only edge ports
and point-to-point links can rapidly transition to forwarding state.
To configure the port as an edge port, set the port to True.
Admin Non STP
The port includes the STP mathematic calculation. True is not
including STP mathematic calculation, false is including the STP
mathematic calculation.
Apply
Click to apply the configurations.
Label
Description
Instance
Set the instance from 1 to 15
State
Enables or disables the instance
VLANs
The VLAN which is mapped to the MSTI. A VLAN can only be
mapped to one MSTI. An unused MSTI will be left empty (ex.
without any mapped VLANs).