![ORiNG TES-3080-M12 Series User Manual Download Page 103](http://html1.mh-extra.com/html/oring/tes-3080-m12-series/tes-3080-m12-series_user-manual_1651980103.webp)
TES-3080-M12(-BP2) User Manual
ORing Industrial Networking Corp
102
port of monitor
function
show monitor
P
Show port monitor
information
switch#show monitor
monitor
[RX|TX|Both]
I
Configure source port
of monitor function
switch(config)#interface fastEthernet
2
switch(config-if)#monitor RX
show monitor
I
Show port monitor
information
switch(config)#interface fastEthernet
2
switch(config-if)#show monitor
no monitor
I
Disable source port of
monitor function
switch(config)#interface fastEthernet
2
switch(config-if)#no monitor
6.11 Commands Set List—802.1x command set
TPS-3082GT-BP1
Commands
Level Description
Example
8021x enable
G
Use the 802.1x global
configuration
command to enable
802.1x protocols.
switch(config)# 8021x enable
8021x system radiousip
[IP address]
G
Use the 802.1x
system radious IP
global configuration
command to change
the radious server IP.
switch(config)# 8021x system
radiousip 192.168.1.1
8021x system serverport
[port ID]
G
Use the 802.1x
system server port
global configuration
command to change
the radious server port
switch(config)# 8021x system
serverport 1815
8021x system
accountport
[port ID]
G
Use the 802.1x
system account port
global configuration
command to change
the accounting port
switch(config)# 8021x system
accountport 1816
8021x system sharekey
G
Use the 802.1x
switch(config)# 8021x system