RGS-PR9000 Series User Manual
ORing Industrial Networking Corp
52
Maximum Frame
You can enter the maximum frame size allowed for the switch port
in this column, including FCS. The allowed range is 1518 bytes to
9600 bytes.
Power Control
Shows the current power consumption of each port in percentage.
The
Configured
column allows you to change power saving
parameters for each port.
Disabled
: all power savings functions are disabled
ActiPHY
: link down and power savings enabled
PerfectReach
: link up and power savings enabled
Enabled
: both link up and link down power savings enabled
Total Power Usage
Total power consumption of the board, measured in percentage
Click to save changes
Click to undo any changes made locally and revert to previously
saved values
Click to refresh the page. Any changes made locally will be
undone.
5.3.2 Port Trunk
This page allows you to configure the aggregation hash mode and the aggregation group.
Label
Description
Source MAC Address
Calculates the destination port of the frame. You can check this
box to enable the source MAC address, or uncheck to disable. By
default,
Source MAC Address
is enabled.
Destination MAC
Address
Calculates the destination port of the frame. You can check this
box to enable the destination MAC address, or uncheck to
disable. By default,
Destination MAC Address
is disabled.
IP Address
Calculates the destination port of the frame. You can check this