RGS-PR9000 Series User Manual
ORing Industrial Networking Corp
140
Press
to run the diagnostics. This will take approximately 5 seconds. If all ports are
selected, this can take approximately 15 seconds. When completed, the page refreshes
automatically, and you can view the cable diagnostics results in the cable status table. Note
that VeriPHY diagnostics is only accurate for cables 7 - 140 meters long.
10 and 100 Mbps ports will be disconnected while running VeriPHY diagnostics. Therefore,
running VeriPHY on a 10 or 100 Mbps management port will cause the switch to stop
responding until VeriPHY is complete
.
Label
Description
Port
The port for which VeriPHY Cable Diagnostics is requested
Cable Status
Port: port number
Pair: the status of the cable pair
Length: the length (in meters) of the cable pair
5.10.6 SFP Monitor
SFP modules with DDM (Digital Diagnostic Monitoring) function can measure the temperature
of the apparatus, helping you monitor the status of connection and detect errors immediately.
You can manage and set up event alarms through DDM Web interface.