IDS-5012 Series
User’s Manual
ORing Industrial Networking Corp
48.
Ethernet to serial
Flush Data Buffer After:
The received data will be queued in the buffer until all the delimiters are matched.
When the buffer is full (4K Bytes) or after "
flush E2S data buffer
" timeout, the data will
also be sent. You can set the time from 0 to 65535 seconds.
Delimiter:
You can define max. 4 delimiters (00~FF, Hex) for each way. The data will be hold until
the delimiters are received or the option “
Flush Ethernet to Serial data buffer
” times
out. 0 means disable. Factory default is 0
Table 5-18 Port Profile
Service Mode
– Virtual COM Mode
In Virtual COM Mode, the driver establishes a transparent connection between host
and serial device by mapping the Port of the serial server serial port to local COM
port on the host computer. Virtual COM Mode also supports up to 5 simultaneous
connections, so that multiple hosts can send or receive data by the same serial
device at the same time.