IDS-5012 Series
User’s Manual
47
ORing Industrial Networking Corp.
Port Profile
Figure 5-29 Port Profile
The following table describes the labels in this screen.
Label
Description
Serial to Ethernet
Flush Data Buffer After:
The received data will be queued in the buffer until all the delimiters are matched.
When the buffer is full (4K Bytes) or after "
flush S2E data buffer
" timeout, the data will
also be sent. You can set the time from 0 to 65535 seconds.
Delimiter:
You can define max. 4 delimiters (00~FF, Hex) for each way. The data will be hold until
the delimiters are received or the option “
Flush Serial to Ethernet data buffer
” times
out. 0 means disable. Factory default is 0