SET THE POSITIONS OF THE GUIDING PLATES
GB
0100-GB LEITBLECHE_384
- 36 -
Dismount guide plate
When spreading it could occur that the left mounted guide plate (LB)
reduces the spread width.
If a greater spread width is required, the guide plate can be
removed.
- Remove ring bolt (1) and washer (2).
- Remove split pin (V) and pull bolt (3) out
- Mount guide plate (LB) onto the top side of the conditioner
- Bolt (3) and split pin (V)
- Ring screw (1) and washer (2)
Important: Washers in the order as shown in diagram
Mount guide plate
For swathing, the guide plate is to be mounted in the position
provided.
- Mounting takes place in the reverse analogical order as by
dismounting.