GB
”DIRECT CONTROL” DEVICE
- 19 -
1000-GB DIRECT CONTROL_384
Setting time difference – Raising/lowering front mower and side mower
Note!
The set times
remain stored
until altered
Switching “time difference function” on/off:
Switching function on:
- Briefly press button 10 “I/O”
- The LEDs change colour to green
- By pressing button 15 all set time differences are
active
Switching function off:
- Briefly press button 10 “I/O”
- The LEDs change colour to red
- By pressing button 15 all mower units are
simultaneously raised or lowered
From 2007 model
Control with dual coloured light emitting diodes
(LEDs)
1. Change to other operation mode
- Briefly press button I/O
- the (LED) changes to green
2. Switch on programming mode:
- Press button 15 for 5 secs.
- The button LED should blink green
Setting time difference - raising
- Put control into programming mode
- Press button B1 (front mower raised)
To set the desired time difference keep pressing
button B1
- When button is released both side mowers are
raised and the time difference is stored.
-
Programming mode ends automatically
Setting time difference - lowering
- Put control into programming mode
- Press button A1 (front mower lowered)
To set the desired time difference keep pressing
button A1
- When button is released both side mowers are
lowered and the time difference is stored
- Programming mode ends automatically
Summary of Contents for NOVACAT 8600
Page 33: ...33 0700 D ROTOR_3841 NOVACAT 8600 Type 384 NOVACAT 8600 Collector Type 3841...
Page 43: ...43 GB EMERGENCY OPERATION 0600 GB Notbedienung_384 screwed out screwed in...
Page 49: ...GB Anhang Titelblatt _BA Allgemein GB SUPPLEMENT...
Page 55: ...55 0600 SCHMIERPLAN_384 FETT...
Page 56: ...56 0600 SCHMIERPLAN_384 FETT...
Page 61: ...0600 GB SERVICE DIRECT CONTROL_384 SERVICE DIRECT CONTROL GB 61...