Installation
15
▐
Installing the
DGM60
equipped with the
AZ
Series
The encoder (ABZO sensor) of the
DGM60
equipped with the
AZ
Series is easily affected by a magnetic field, so
make sure the installation location.
When motors are installed side by side, ensure distances in horizontal and vertical directions of more than the frame
size of the other motor installed.
A mm
(A in.)
A mm
(A in.)
A mm
(A in.)
A mm
(A in.)
Motor frame size
A mm (A in.) *
A mm
(A in.)
A mm
(A in.)
A mm
(A in.)
z
Reference
Other motor
A
Frame size 20 mm (0.79 in.)
20 mm (0.79 in.)
Frame size 28 mm (1.10 in.)
28 mm (1.10 in.)
Frame size 42 mm (1.65 in.)
42 mm (1.65 in.)
Frame size 60 mm (2.36 in.)
60 mm (2.36 in.)
* Ensure distances of more than the frame size
[A mm (A in.)] of the other motor.
4-2
Installation direction
The actuator can be installed in any direction.
To prevent vibration, install the actuator on a metal surface of sufficient strength.
•
On rare occasions, a small amount of grease may ooze out from the actuator. If there is concern
over possible environmental damage resulting from the leakage of grease, check for grease stains
during regular inspections. Alternatively, install an oil pan or other device to prevent leakage from
causing further damage. Oil leakage may lead to problems in the user’s equipment or products.
•
Do not loosen or remove the screws of the actuator. Doing so may cause the positioning accuracy
to drop or damage to the actuator.
•
Be sure the positioning pins are secured to the mounting plate. Driving the pins into the actuator
may damage the actuator due to impact.
•
Do not drop the actuator. Also, do not hit the motor or gear-reduction mechanism on something
hard. Doing so may cause the positioning accuracy decrease, the motor section damage or the
product service life reduction.
4-3
Release the electromagnetic brake type
When moving the table of the electromagnetic brake type manually, connect the 24 VDC power supply for
electromagnetic brake to release the electromagnetic brake.
z
Specifications of a power supply for electromagnetic brake
Model
Voltage
Current capacity
DGM85
24 VDC±5% *
0.08 A or more
DGM130
,
DGM200
0.25 A or more
* If the distance between an actuator with an electromagnetic brake and driver is extended to the following length,
use a power supply of 24±4% VDC.
Actuator equipped with the
AZ
Series : 20 m (65.6 ft.)
Actuator equipped with the
AR