5.9.1.9 FXS Advanced Default Settings
FXS Gain: -7.0
Hookflash Min (ms) : 75
Hookflash Max (ms) : 800
Hook Status Changes (ms) : 50
5.9.1.10 Default IP Advanced Settings
RTP Jitter Max (Frame) : 50
RTP Jitter Min (Frame) : 3
2833 Packet Type: 100
Send Busy Tone for Network Breakdown: off
Switch to FXO for Network Breakdown: on
Generation of the Mute Compress and Comfort Noise: yes
G.723.1 Rate (BPS) : 6300
IP Packet in Tos Field: 0x0C T.38: off
T.38 Data Frame Length (ms) : 40
T.38 Redundancy Fram Number: 4
T.38 Change UDP Port: no
T.38 Error Detect Mode: off
5.9.1.11 SIP Advanced Default Settings
Response Default Port Using Received Port: no
Response Default Port Using Proxy Port: no
RTP Port Mapping: no
Replace 18x with 180: no
Replace 18x with 183: no
180 with SDP: no
CPN from Request Line: no
Response Do Not Check Via: yes
Use the Full Domain Name Information during Registering: yes
Keep the Original Contact Information: no
SIP VIA using NAT Information: yes
SIP TO adopt Domain Name Information: yes
Maximal Forwarding Times of Signaling: 60
Timer A (ms) : 500
Timer B (ms) : 32000