66
| INSTRUCTIONS FOR USE
OMD 202RS
SETTING
PROFI
6.
6.4
SETTING “PROFI” - SERVICE
6.4.1
SETTING THE ADDRESS OF IR REMOTE CONTROL
R
CHANNE.
SERVIC.
OUTPUT.
MENU
LANG.
INPUTS
N. PASS.
RESTOR.
IDENT.
ADR. IR.
The instrument service functions are
set in this menu
ADR. IR.
Setting the address of
IR control
MENU
Selection of menu type
LIGHT/PROFI
RESTOR.
Restore instrument
manufacture setting and
calibration
LANG.
Language version of
instrument menu
N. PASS.
Setting new access
password
IDENT.
Instrument identification
R
CHANNE.
SERVIC.
OUTPUT.
ADR. IR.
RESTOR.
LANG.
INPUTS
N. PASS.
0
IDENT.
MENU
ADR. IR.
Setting the address of
IR remote control
- setting the remote control address is inevitable
only in case there are other large displays
OMD 202 within the reach of IR remote control
- range of the setting: 0…99
-
DEF
= 0
Controlling addressed instrument
- if the OMD has an address different than „0“
- press the green button and key in the address
of the controlled device
- after establishing communication a yellow
signalling LED lights up on the display
- then you can control the dispaly in the standard
way in LIGHT/PROFI/USER menu
- if needed, the address can cancelled by
pressing the blue button of the remote