Setting the time constant
for Timeout
- setting the time delay after which the indication
of interrupted communication will appear on
the display in the mode of „
MOD. t.0
“
- range: 0…99,9 s
-
DEF
= 1,0 s
Item will appear only in “
SLAVE
” and when
„
MOD. T.0
“ is enable
!
R
CHANNE.
SERVIC.
OUTPUT.
CLEAR
EXT. IN.
CONFIG.
KEYS
INPUTS
U.INT.16
DEF
COMMAN.
PROT.
ADDR..
BAUD
REGIST.
MOD. T.O
ORDER
MIN
MAX
TIMEOU.
FORMAT
S.INT.16
U.INT.32
S.INT.32
FLOAT
FORMAT
Selection of the format of
input data
U.INT.16
16-bit unsign integer
- range: 0…65 535
S.INT.16
16-bit sign integer
- range: -32 768…32 767
U.INT.32
32-bit unsign integer
- range: 0…4 294 967 296
S.INT.32
32-bit sign integer
- range: -2 147 483 648…2 147 483 644
FLOAT
IEEE format
- range: ±6,8056469338
- for description see table on page 72