| INSTRUCTIONS FOR USE
OMD 202RS
SETTING
PROFI
6.
6.1.2j
SETTING INPUT VALUE
MAX.
R
CHANNE.
SERVIC.
OUTPUT.
CLEAR
EXT. IN.
CONFIG.
KEYS
INPUTS
ORDER
MIN.
PROT.
BAUD
ADDR.
FORMAT
COMMAN. .
REGIST.
MOD T.O.
TIMEOU.
MAX. LO
MAX. HI
MIN.
R
CHANNE.
SERVIC.
OUTPUT.
CLEAR
EXT. IN.
CONFIG.
KEYS
INPUTS
ORDER
MAX.
PROT.
BAUD
ADDR.
FORMAT
COMMAN.
REGIST.
MOD T.O.
TIMEOU.
MIN. LO
MIN. HI
CONFIG.
Setting input value
„FORMAT“ > U.INT.16/S.INT.16
- range of the setting: 0…65 535
MIN Lo
Setting mimum value of
input data
MIN Lo
DEF
= 0 (U.INT.16)
MIN Lo
DEF
= 32 768 (S.INT.16)
MAX Lo
Setting maximum value of
input data
MAX Lo
DEF
= 65 535 (U.INT.16)
MAX Lo
DEF
= 32 767 (S.INT.16)
„FORMAT“ > U.INT.32/S.INT.32
- range of the setting: -99 999…999 999
- setting the range of input values “Long
integer” number in two values (words) “
MIN Lo
”,
“
MIN Hi
” and “
MAX Lo
”, “
MAX Hi
”
- to set minimum/maximum divide the values
by 65536, split the outcome to two parts and
enter to “
MIN Lo
” and “
MIN Hi
” /“
MAX Lo
” and
“
MAX Hi
”
MIN --
Setting mimum value of
input data
MIN Lo
DEF
= 0 (U.INT.32)
MIN Hi
DEF
= 0 (U.INT.32)
MIN Lo
DEF
= 0 (S.INT.32)
MIN Hi
DEF
= 32 768 (S.INT.32)
MAX --
Setting maximum value of
input data
MAX Lo
DEF
= 65 535 (U.INT.32)
MAX Hi
DEF
= 65 535 (U.INT.32)
MAX Lo
DEF
= 65 535 (S.INT.32)
MAX Hi
DEF
= 32 767 (S.INT.32)
„FORMAT“ > FLOAT
- range of the setting: -99 999…999 999
MIN
Setting mimum value of
input data
DEF
= 0
MAX
Setting maximum value of
input data
DEF
= 100