18
| INSTRUCTIONS FOR USE
OMD 202RS
FORMAT
Selection of the format of
input data
DEF
= U. INT. 16
M
O
.T.
O
..
Menu
Popis
U.INT.16
16 bit unsigned integer in the range 0…65 535
S.INT.16
16 bit signed integer in the range -32 768…32 767
U.INT.32
32 bit unsigned integer in the range 0…4 294 967 296
S.INT.32
32 bit signed integer in the range -2 147 483 648…2 147 483 647
FLOAT
IEEE Format, see table
SETTING
LIGHT
5.
R
U.INT.16
S.INT.16
Selection of the format > FORMAT = U.INT.16
Example
FORMAT
U.INT.16
MIN LO
FLOAT
S.INT.32
U.INT.32
FORMAT
ORDER
COMMAND
DATA
U. INT. 16
n/a
0x06
<AA> 06 00 00 <Word Hi> <Word Lo> <CRC Lo> <CRC Hi>
S. INT. 16
n/a
0x06
<AA> 06 00 00 <Word Hi> <Word Lo> <CRC Lo> <CRC Hi>
U. INT. 32
LO - HI
0x10
<AA> 10 00 00 00 02 04 <Lo Word Hi> <Lo Word Lo> <Hi Word Hi> <Hi Word Lo> <CRC Lo> <CRC Hi>
S. INT. 32
LO - HI
0x10
<AA> 10 00 00 00 02 04 <Lo Word Hi> <Lo Word Lo> <Hi Word Hi> <Hi Word Lo> <CRC Lo> <CRC Hi>
FLOAT
LO - HI
0x10
<AA> 10 00 00 00 02 04 <Lo Word Hi> <Lo Word Lo> <Hi Word Hi> <Hi Word Lo> <CRC Lo> <CRC Hi>
U. INT. 32
HI - LO
0x10
<AA> 10 00 00 00 02 04 <Hi Word Hi> <Hi Word Lo> <Lo Word Hi> <Lo Word Lo> <CRC Lo> <CRC Hi>
S. INT. 32
HI - LO
0x10
<AA> 10 00 00 00 02 04 <Hi Word Hi> <Hi Word Lo> <Lo Word Hi> <Lo Word Lo> <CRC Lo> <CRC Hi>
FLOAT
HI - LO
0x10
<AA> 10 00 00 00 02 04 <Hi Word Hi> <Hi Word Lo> <Lo Word Hi> <Lo Word Lo> <CRC Lo> <CRC Hi>
LEGEND
SIGN
DESCRIPTION
#
Beginning of command
<AA>
Instrument address (1…247)
<Word xx>
16-bit data
<Lo Word xx>
32-bit data (lower part)
<Hi Word xx>
32-bit data (higher part)