36
| INSTRUCTIONS FOR USE
OM 402PID
SETTING
LIGHT
5.
DERIV.
Setting of derivative constant
- range of the setting: 0…999999
DEF
= 1.00
DERIV.
1.00
Setting of derivative
constant
Setting of derivative constant > DERIV. = 1.3
Example
1.0
0
1.
1
0
1.
0
0
1.
3
0
1.
2
0
OUTAGE
OFF
Selection of function during a power failure - j / OUTAGE = CONTIN.
Example
OFF
FIX
LIM. L.1
CONTIN.
FIX
OUTAGE
OUTAGE
Selection of function during
a power failure
DEF
= OFF
Menu item „
ANALOG
“ can be accessed only if the
unit if fitted with input “Requested value”
OUT
AGE
Menu
Function
OFF
Control process switches off
FIX
Control to a fixed value
ANALOG.
Control process will be controlled
by analogue input “Setpoint”
CONTIN..
Control process will be resumed
from the moment of power loos
STEP
Control process will be resumed
from the beginning of the last step
PROG.
Control process will be resumed
from the beginning of the last
program
38
AN. OUT.
CONTIN.
STEP
PROG.