5-8
TROUBLESHOOTING
ORBAN MODEL 8685
A)
You may have the wrong interface type set on your 8685.
L
OCATE
to
S
ETUP
>
N
ETWORK
&
R
EMOTE
>
N
ETWORK
>
S
ERIAL
I
NTERFACE
T
YPE
and check the interface
setting. See
Connecting to the 8685’s Ethernet Port or RS-232 Port Using
TCP/IP
on page 2-52.
B)
If you are connecting via Direct Serial Connection or modem, review the
Properties you have set on that connection. Double-check to ensure that you
have set Windows parameters as described in
Appendix: Setting Up Serial
Communications
on page 2- 67.
•
If your Direct Connect does not work:
A)
Check to make sure that the cables are connected properly.
B)
Check that you are using a null modem cable.
C)
Ensure that the null modem cable is connected to the 8685’s serial connector.
•
If your Modem Connect does not work:
A)
Ensure that the modem cables and phone lines are connected properly.
B)
Check that you have entered the correct phone number for connection.
C)
Check that you have entered the passcode correctly on the 8685 and the pass-
code has been entered correctly on your PC.
D)
Ensure that you enabled the correct PC modem port settings.
E)
Ensure that the external modem attached to your 8685 is set to
A
UTO
A
NSWER
.
F)
Make sure that the only “Allowed Network Protocol” is TCP/IP. “NetBUI” and
“IPX > SPX Compatible” must
not
be checked.
•
If you cannot connect to your computer through a crossover Ethernet cable:
You must set your Windows networking to provide a static IP address for
your computer because your Optimod does not contain a DHCP server.
You Cannot Access the Internet After
Making a Direct or Modem Connection to the 8685:
If you are connected to the 8685 via modem or direct connect,
you cannot access
any other TCP/IP connection
. The PPP connection becomes the default protocol
and the default gateway defaults to the 8685 unit’s IP address. This means that
all existing network connections point to the 8685 unit. To correct this:
A)
In Start > Settings > Network and Dialup Connections, open the direct or mo-
dem connection you are using to connect to 8685.
B)
Select “Properties.”
C)
Click the tab that reads “Networking.”
D)
Highlight “Internet protocol (TCP/IP).”
E)
Select “Properties.”
Summary of Contents for OPTIMOD 8685
Page 1: ...Operating Manual OPTIMOD 8685 Surround Audio Processor Version 1 0 Software...
Page 7: ...Operating Manual OPTIMOD 8685 Surround Audio Processor Version 1 0 Software...
Page 28: ...X XLR connector wiring standard 2 8...
Page 54: ......
Page 120: ...2 66 INSTALLATION ORBAN MODEL 8685 NOTES...
Page 144: ......
Page 244: ......
Page 293: ...OPTIMOD SURROUND PROCESSOR TECHNICAL DATA 6 37...
Page 299: ...OPTIMOD SURROUND PROCESSOR TECHNICAL DATA 6 43 CPU MODULE Drawing 32200 000 02...
Page 327: ...OPTIMOD SURROUND PROCESSOR TECHNICAL DATA 6 71 LCD CARRIER PARTS LOCATOR 32270 000...
Page 332: ...6 76 TECHNICAL DATA ORBAN MODEL 8685 FRONT PANEL INTERFACE BOARD PARTS LOCATOR DRAWING...
Page 357: ...OPTIMOD SURROUND PROCESSOR TECHNICAL DATA 6 101...