2-40
INSTALLATION
ORBAN MODEL 8685
tion (like a user’s interacting with the front panel or with the PC Remote
application).
c)
L
OCATE
to the Event Type field and set the desired event. You can recall any
factory processing preset, user processing preset, and Setup. You can
activate
B
YPASS
mode (for scheduled transmission network testing),
T
ONE
,
and
E
XIT
T
EST
, which returns you to the processing preset that was active
before you invoked
T
ONE
or
B
YPASS
.
Although two Setups might only differ by one parameter (for example,
different values of
S
URROUND
D
IALNORM
), recalling Setups also provides an
easy way to automate complicated changes involving many parameters
like input/output routing.
D)
For
S
ET
B
Y
D
ATE
, set the desired date and time for the event and specify the
Event Type.
E)
Choose
D
ONE
and press
E
NTER
.
You will return to the automation event list.
You may have to scroll the
list (using the knob) to see the event that you just added
.
5.
To edit an existing event:
A)
Using the knob, highlight the event you wish to edit.
B)
Select the
E
DIT
button and press
E
NTER
. The edit screen appears.
C)
Edit the event as desired.
D)
When you have finished making edits, choose
D
ONE
and press
E
NTER
.
6.
To delete an event:
A)
Highlight the event to delete with the knob.
B)
Choose
D
ELETE
and press
E
NTER
.
7.
Choose
D
ONE
and press Enter to leave the Automation screen.
Security and Passcode Programming
You can use multi-level passcodes to control access to the 8685 via the front panel
and via PC Remote. You can configure a given passcode to allow one of the follow-
ing levels of access:
1. All Access (i.e., administrator level)
2. All Access except Security
3. All screens except Modify and Security
4. Recall, Modify, and Automation
5. Recall Presets and program Automation
Summary of Contents for OPTIMOD 8685
Page 1: ...Operating Manual OPTIMOD 8685 Surround Audio Processor Version 1 0 Software...
Page 7: ...Operating Manual OPTIMOD 8685 Surround Audio Processor Version 1 0 Software...
Page 28: ...X XLR connector wiring standard 2 8...
Page 54: ......
Page 120: ...2 66 INSTALLATION ORBAN MODEL 8685 NOTES...
Page 144: ......
Page 244: ......
Page 293: ...OPTIMOD SURROUND PROCESSOR TECHNICAL DATA 6 37...
Page 299: ...OPTIMOD SURROUND PROCESSOR TECHNICAL DATA 6 43 CPU MODULE Drawing 32200 000 02...
Page 327: ...OPTIMOD SURROUND PROCESSOR TECHNICAL DATA 6 71 LCD CARRIER PARTS LOCATOR 32270 000...
Page 332: ...6 76 TECHNICAL DATA ORBAN MODEL 8685 FRONT PANEL INTERFACE BOARD PARTS LOCATOR DRAWING...
Page 357: ...OPTIMOD SURROUND PROCESSOR TECHNICAL DATA 6 101...