2-54
INSTALLATION
ORBAN MODEL 8685
The IP address for this connection is the same as the IP address set in step
(1.A) on page 2-56 and is visible in the
S
YSTEM
S
ETUP
>
N
ETWORK
R
EMOTE
>
N
ETWORK
screen
.
E)
Name and save the Session if you wish.
F)
Click
O
PEN
.
G)
Activate the
C
APS
L
OCK
on your computer to ensure that you type in upper-
case.
You can now recall presets and Setups. Refer to step 1 on page 2-47 and
step 2 on page 2-48.
Using the API: Example
These examples show how PuTTY and Plink can be used to control the Optimod us-
ing scripting and batch files on a computer connected to the same Ethernet subnet
as the Optimod being controlled. Plink and all associated scripting text, PuTTY, and
batch files should be located together in the same user-defined directory unless the
path is specified in the .bat files.
In the example, replace “192.168.1.1” with the addressed Optimod’s IP address and
“23” with the Optimod’s port number. 23 is the default; see step (B) on page 2-53.
Replace “passcode” with a passcode having any access level (because all levels allow
you to recall presets). See
Security and Passcode Programming
on page 2-40.
Each control session requires two ASCII files:
•
a .bat file that calls Plink to establish a Telnet connection to the Optimod
•
a reference.txt file that contains the actual control script.
Recalling a Processing Preset
This function will recall the
TV
5B
D
RAMA
factory preset and put it on-air. (See
step 1 on page 2-47.)
The file “recall_tv_5b_drama.bat” contains:
plink -telnet -P 23 192.168.1.1 < recall_tv_5b_drama.txt
The file “recall_tv_5b_drama.txt” contains:
RP TV 5B DRAMA[password]
disconnect
Remote Control Interface Programming
This section describes how to program the opto-isolated GPI remote control inter-
face. See step 5 on page 2-3 for wiring instructions.
Summary of Contents for OPTIMOD 8685
Page 1: ...Operating Manual OPTIMOD 8685 Surround Audio Processor Version 1 0 Software...
Page 7: ...Operating Manual OPTIMOD 8685 Surround Audio Processor Version 1 0 Software...
Page 28: ...X XLR connector wiring standard 2 8...
Page 54: ......
Page 120: ...2 66 INSTALLATION ORBAN MODEL 8685 NOTES...
Page 144: ......
Page 244: ......
Page 293: ...OPTIMOD SURROUND PROCESSOR TECHNICAL DATA 6 37...
Page 299: ...OPTIMOD SURROUND PROCESSOR TECHNICAL DATA 6 43 CPU MODULE Drawing 32200 000 02...
Page 327: ...OPTIMOD SURROUND PROCESSOR TECHNICAL DATA 6 71 LCD CARRIER PARTS LOCATOR 32270 000...
Page 332: ...6 76 TECHNICAL DATA ORBAN MODEL 8685 FRONT PANEL INTERFACE BOARD PARTS LOCATOR DRAWING...
Page 357: ...OPTIMOD SURROUND PROCESSOR TECHNICAL DATA 6 101...