1.
Locate to the System Setup > Network Remote > Remote Interface
screen.
2.
Program one or more remote control interfaces.
To program a given remote input, use
L
OCATE
to highlight the input. As you turn
the control knob, the functions listed below will appear in the highlighted field.
A momentary pulse of current will switch most functions, except as noted.
•
Preset Name
: activates that processing preset.
Any factory or user preset can be recalled via the control interface.
Presets programmed into the Remote Interface can be recalled more
quickly than they can via the 8685’s front panel or PC Remote. If you
need to recall a preset within one video frame, we advise using the Re-
mote Interface to do so. This advice also applies to the
P
ASS
-T
HROUGH
preset and user presets based on it.
Application example:
By saving your active preset as two User Presets,
identical except that one has the 8685’s Loudness Controller turned on
and one has it turned off, you can use the GPI inputs to smoothly activate
and defeat the Loudness Controller by recalling the appropriate User Pre-
set.
•
Setup Name
: activates that Setup.
You can save multiple setups that do things like changing the global
D
IALNORM
value and reassigning inputs and outputs in the routing
switcher.
•
Bypass
: switches the Bypass Test Mode on the air.
Note that this is a
test mode
; to smoothly defeat the audio processing ex-
cept for peak limiting (to accommodate network program pass-through,
for example), recall the factory
P
ASS
-T
HROUGH
preset or, if you need a dif-
ferent bypass gain than the factory
P
ASS
-T
HROUGH
preset provides, a user
preset you have edited and saved based on the
P
ASS
-T
HROUGH
preset.
•
Tone
: switches a Tone Test on the air.
•
Exit Test
: If a test mode (Tone or Bypass) is switched on the air,
EXIT TEST
re-
verts to the normal operating mode using the previous processing preset.
•
Reset Clock To Hour
Note that it is usually more convenient to synchronize your 8685 to a
network timeserver than to use this function. See
Synchronizing Optimod
to a Network Timeserver
on page 2-59.
•
Reset to Midnight
(See the note immediately above.)
•
No Function
: remote input is disabled.
Summary of Contents for OPTIMOD 8685
Page 1: ...Operating Manual OPTIMOD 8685 Surround Audio Processor Version 1 0 Software...
Page 7: ...Operating Manual OPTIMOD 8685 Surround Audio Processor Version 1 0 Software...
Page 28: ...X XLR connector wiring standard 2 8...
Page 54: ......
Page 120: ...2 66 INSTALLATION ORBAN MODEL 8685 NOTES...
Page 144: ......
Page 244: ......
Page 293: ...OPTIMOD SURROUND PROCESSOR TECHNICAL DATA 6 37...
Page 299: ...OPTIMOD SURROUND PROCESSOR TECHNICAL DATA 6 43 CPU MODULE Drawing 32200 000 02...
Page 327: ...OPTIMOD SURROUND PROCESSOR TECHNICAL DATA 6 71 LCD CARRIER PARTS LOCATOR 32270 000...
Page 332: ...6 76 TECHNICAL DATA ORBAN MODEL 8685 FRONT PANEL INTERFACE BOARD PARTS LOCATOR DRAWING...
Page 357: ...OPTIMOD SURROUND PROCESSOR TECHNICAL DATA 6 101...