Determine Which Processor Module Is Faulty
■
“Verify a Processor Module” on page 67
Determine Which Processor Module Is Faulty
The following LEDs are lit when a processor module fault is detected:
■
Front and rear System Fault (Service Required) LEDs
■
Service Required LED on the faulty processor module
1.
Determine if the Service Required LEDs are illuminated on the front panel or the
rear I/O module.
See
“Interpreting LEDs” on page 27
2.
From the front of the server, check the processor module LEDs to identify which
processor module needs to be replaced.
See
“Processor Module LEDs” on page 59
. The amber Service Required LED is lit on the
processor module that needs to be replaced.
3.
Remove the faulty processor module.
See
“Remove a Processor Module or Processor Filler Module” on page 60
.
Related Information
■
“Processor Module Components” on page 19
■
“Processor Module LEDs” on page 59
■
“Remove a Processor Module or Processor Filler Module” on page 60
■
“Install a Processor Module or Processor Filler Module” on page 64
■
“Verify a Processor Module” on page 67
Remove a Processor Module or Processor Filler Module
Processor modules and processor filler modules are cold-service components that can be
replaced only after you power off the system. Processor modules can be replaced only
by qualified service personnel. For the location of the modules, see
.
Caution -
You must disconnect the power cords before servicing this component. See
“Disconnect Power Cords” on page 53
.
60
SPARC T7-4 Server Service Manual • May 2017
Summary of Contents for SPARC T7-4
Page 1: ...SPARC T7 4 Server Service Manual Part No E54994 07 May 2017 ...
Page 2: ......
Page 10: ...10 SPARC T7 4 Server Service Manual May 2017 ...
Page 12: ...12 SPARC T7 4 Server Service Manual May 2017 ...
Page 86: ...86 SPARC T7 4 Server Service Manual May 2017 ...
Page 98: ...98 SPARC T7 4 Server Service Manual May 2017 ...
Page 110: ...110 SPARC T7 4 Server Service Manual May 2017 ...
Page 124: ...124 SPARC T7 4 Server Service Manual May 2017 ...
Page 142: ...142 SPARC T7 4 Server Service Manual May 2017 ...
Page 164: ...164 SPARC T7 4 Server Service Manual May 2017 ...
Page 192: ...192 SPARC T7 4 Server Service Manual May 2017 ...
Page 200: ...200 SPARC T7 4 Server Service Manual May 2017 ...
Page 208: ...208 SPARC T7 4 Server Service Manual May 2017 ...