Rear I/O Module LEDs
No.
LED
Icon
Description
7
System Locator LED and
button (white)
The Locator LED can be turned on to identify a particular server. When
on, it blinks rabidly. There are two methods for turning a Locator LED
on:
■ Issuing the Oracle ILOM command
set /SYS/LOCATE
value=Fast_Blink
■ Pressing the Locator button
8
System Service Required
LED (amber)
Indicates that service is required. POST and Oracle ILOM are two
diagnostic tools that can detect a fault or failure resulting in this
indication.
The Oracle ILOM
show faulty
command provides details about any
faults that cause this indicator to illuminate.
The System Service Required LED also illuminates on the rear I/O
module if the rear I/O module has failed.
9
System Power OK LED
(green)
Indicates the following conditions:
■
Off
– Server is not running in its normal state. Server power might
be off. The SPM might be running.
■
Steady on
– Server is powered on and is running in its normal
operating state. No service actions are required.
■
Fast blink
– Server is running in standby mode and can be quickly
returned to full function.
■
Slow blink
– A normal but transitory activity is taking place. Slow
blinking might indicate that server diagnostics are running or the
server is booting.
10
Service Processor LED
SP
Indicates the following conditions:
■
Off
– The AC power might have been connected to the power
supplies.
■
Steady on, green
– The SPM is running in its normal operating
state. No service actions are required.
■
Blink, green–
The SPM is initializing the Oracle ILOM firmware.
■
Steady on, amber
– A SPM error has occurred and service is
required.
11
Overtemperature
Indicates the following conditions:
■
Off
– Server is powered on and is running in its normal operating
state, or it is powered off (no overtemperature fault present).
■
Steady on, amber
– An overtemperature fault has been detected.
Related Information
■
“Determine if the Rear I/O Module Is Faulty” on page 186
■
“Remove the Rear I/O Module” on page 186
■
“Install the Rear I/O Module” on page 188
Servicing the Rear I/O Module
185
Summary of Contents for SPARC T7-4
Page 1: ...SPARC T7 4 Server Service Manual Part No E54994 07 May 2017 ...
Page 2: ......
Page 10: ...10 SPARC T7 4 Server Service Manual May 2017 ...
Page 12: ...12 SPARC T7 4 Server Service Manual May 2017 ...
Page 86: ...86 SPARC T7 4 Server Service Manual May 2017 ...
Page 98: ...98 SPARC T7 4 Server Service Manual May 2017 ...
Page 110: ...110 SPARC T7 4 Server Service Manual May 2017 ...
Page 124: ...124 SPARC T7 4 Server Service Manual May 2017 ...
Page 142: ...142 SPARC T7 4 Server Service Manual May 2017 ...
Page 164: ...164 SPARC T7 4 Server Service Manual May 2017 ...
Page 192: ...192 SPARC T7 4 Server Service Manual May 2017 ...
Page 200: ...200 SPARC T7 4 Server Service Manual May 2017 ...
Page 208: ...208 SPARC T7 4 Server Service Manual May 2017 ...