Install a DIMM
Install a DIMM
Caution -
This procedure requires handling components that are sensitive to ESD.
to avoid damage or component failure.
DIMMs are installed:
■
■
■
replacing a faulty motherboard
.
To ensure proper airflow, DIMM fillers must be installed if you are downgrading memory in the
server, or are replacing a faulty memory riser without upgrading memory.
You can perform this procedure, but the server must first be completely powered down and all
power cords unplugged. See
“Component Service Categories” on page 50
for more information
about cold-service procedures.
Caution -
Whenever you remove a DIMM, you should replace it with another DIMM before
applying power to the server. Otherwise, the server might overheat due to improper airflow.
1.
Attach an antistatic wrist strap.
Then unpack the DIMMs and place them on an antistatic mat.
104
SPARC T7-2 Server Service Manual • July 2019
Summary of Contents for SPARC T7-2
Page 1: ...SPARC T7 2 Server Service Manual Part No E54987 10 July 2019 ...
Page 2: ......
Page 10: ...10 SPARC T7 2 Server Service Manual July 2019 ...
Page 12: ...12 SPARC T7 2 Server Service Manual July 2019 ...
Page 28: ...28 SPARC T7 2 Server Service Manual July 2019 ...
Page 64: ...64 SPARC T7 2 Server Service Manual July 2019 ...
Page 84: ...84 SPARC T7 2 Server Service Manual July 2019 ...
Page 112: ...112 SPARC T7 2 Server Service Manual July 2019 ...
Page 116: ...116 SPARC T7 2 Server Service Manual July 2019 ...
Page 120: ...120 SPARC T7 2 Server Service Manual July 2019 ...
Page 134: ...134 SPARC T7 2 Server Service Manual July 2019 ...
Page 146: ...146 SPARC T7 2 Server Service Manual July 2019 ...
Page 164: ...164 SPARC T7 2 Server Service Manual July 2019 ...
Page 170: ...170 SPARC T7 2 Server Service Manual July 2019 ...
Page 176: ...176 SPARC T7 2 Server Service Manual July 2019 ...
Page 182: ...182 SPARC T7 2 Server Service Manual July 2019 ...
Page 188: ...188 SPARC T7 2 Server Service Manual July 2019 ...