Remove a Fan Module
You can perform this procedure while the server is running. See
for more information about hot-service procedures.
1.
Prepare for servicing.
a.
Attach an antistatic wrist strap.
See
“Prevent ESD Damage” on page 50
b.
Extend the server to the maintenance position.
See
“Extend the Server to the Service Position” on page 51
2.
Open the fan door.
Slide the two green buttons to unlock the fan door, then swing it open.
3.
Identify the faulty fan module with a corresponding Service Required LED.
76
SPARC T7-1 Server Service Manual • May 2017