Install a Power Supply
See
“Remove a Power Supply” on page 84
.
2.
If necessary, release the CMA to access the power supplies.
See
Do not allow the CMA to hang unsupported while it is unattached.
3.
Align the power supply with the empty power supply chassis bay.
4.
Slide the power supply into the bay until it is fully seated.
You will hear an audible click when the power supply is fully seated.
5.
Reconnect the power cord to the power supply.
6.
If you disconnected the two CMA left-side connectors, reconnect the CMA.
For instructions on reconnecting the CMA see
“Attach the CMA to the Server” in
7.
Verify that the AC OK LED is lit.
86
SPARC T7-1 Server Service Manual • May 2017