Replace the Battery
->
show -d properties /SP/clock
Properties
datetime = Mon Aug 22 13:20:16 2016
timezone = EDT (EST5EDT)
uptime = 2 days 19:56:49
usentpserver = disabled
b.
If the SP policy
HOST_POWER_ON
was enabled before you replaced the battery,
you must re-enable it.
->
set /SP/policy HOST_POWER_ON=enabled
c.
If the
/SP/clock
usentpserver
property was enabled before you replaced the
battery, you must re-enable it.
->
set /SP/clock usentpserver=enabled
4.
Verify the battery.
->
show /SYS/MB/BAT
Related Information
■
“Identify Faulted Components” on page 24
Servicing the Battery
129