The power source must be easily accessible because the power cord is the main
disconnect device for the disk shelf.
1.
Plug the two power cords into the universal power connectors.
2.
Connect the cords to the external power source.
3.
Turn on the disk shelf power switches.
4.
Wait several minutes until the power indicators are lit a steady green.
Related Topics
•
•
Powering On a Controller
Use the following procedure to power on an Oracle ZFS Storage Appliance controller.
1.
Plug power cables into power supply 0 and power supply 1 on the storage controller(s).
2.
Connect cables to the external power source.
The controller automatically powers on.
3.
Wait until the Power/OK LED on the front panel next to the Power button lights and
remains lit (approximately two minutes).
If the Service Required amber indicator is lit, see
in Oracle ZFS Storage Appliance Customer Service Manual, Release
OS8.8.x. Also see the Oracle ILOM documentation located in the documentation library
for this software release at
https://docs.oracle.com/en/storage/index.html
Related Topics
Powering Off a Controller
The recommended methods for powering off a controller depend on whether you have
completed initial configuration. Use a power-off method from one of the following two
situations.
If you have completed initial configuration, power off the controller using one of the following
methods:
•
Log in to the BUI and click the power icon on the left side under the masthead.
•
SSH in to the appliance and enter the command
maintenance system poweroff
.
•
Use a pen or non-conducting pointed object to press and release the Power button on the
front panel.
If you have not completed the initial configuration steps, power off the controller using one of
the following methods:
•
Use a pen or non-conducting pointed object to press and release the Power button on the
front panel.
•
SSH or use a serial connection to log in to the service processor (SP), and then issue the
command
stop /SYS
.
Chapter 12
Powering On a Controller
12-3