Contacting Technical Support
■
76° C - Drive write throttling is engaged to reduce SSD power.
■
SSD amber status indicator is lit, Service Action Required.
See
“Status Indicators” on page 12
■
First threshold for Dynamic Thermal Throttling (DTT). Critical temperature status
displays in utility output:
Critical warning 1
‐
Temperature exceeded critical
threshold.
Use the Oracle Hardware Management Pack CLI commands to determine the
temperature and status of the Oracle 3.2 TB NVMe SSD. See
Oracle Flash Accelerator F320 PCIe Card and Oracle 3.2
■
83° C SSD I/O stop overtemp critical limit.
■
SSD component shuts down.
■
Critical temperature status displays in utility output:
Critical warning 1
‐
Temperature exceeded critical threshold
.
Use the Oracle Hardware Management Pack CLI commands to determine the
temperature and status of the Oracle 3.2 TB NVMe SSD. See
Oracle Flash Accelerator F320 PCIe Card and Oracle 3.2
The following image shows the Oracle 3.2 TB NVMe SSD temperature sensor location:
(1): SSD temperature sensor location
Related Information
■
“Status Indicators” on page 12
■
■
“Technical Support” on page 40
42
Oracle 3.2 TB NVMe SSD User Guide • July 2016