36
Firmware version 1.10 - Document version 1.06 - eng
LTDVE1CH-40F | INSTRUCTIONS MANUAL
65535
352
CAL_MES_TMP_REM1_ADD
R
0-
65535
Calibration constant
353
CAL_MES_VLT_SUP_MUL
R
0-
65535
Calibration constant
354
CAL_MES_VLT_SUP_ADD
R
0-
65535
Calibration constant
355
CAL_MES_VLT_CNV_MUL
R
0-
65535
Calibration constant
356
CAL_MES_VLT_CNV_ADD
R
0-
65535
Calibration constant
357
CAL_MES_VLT_DRV_MUL
R
0-
65535
Calibration constant
358
CAL_MES_VLT_DRV_ADD
R
0-
65535
Calibration constant
359
CAL_MES_CUR_SUP_MUL
R
0-
65535
Calibration constant
360
CAL_MES_CUR_SUP_ADD
R
0-
65535
Calibration constant
361
CAL_MES_CUR_DRV_MUL
R
0-
65535
Calibration constant
362
CAL_MES_CUR_DRV_ADD
R
0-
65535
Calibration constant
363
CAL_UNLOCK_CODE0
R
0-
65535
Unlock code 0 for the calibration
constants
364
CAL_UNLOCK_CODE1
R
0-
65535
Unlock code 1 for the calibration
constants
365-510
RESERVED
N/A N/A
Reserved for future use
511
BOARD_COMMAND
RW 0-3
Board command
Table 14: controller register file
As indicated in the table, most of the registers can be both read and written (type RW), some
registers are read only (type R) and some others are unused or reserved (type N/A). Registers
marked as unused or reserved must not be accessed, either in reading and writing, at any time.
Failure to comply with this requirement may lead to device malfunction. The accessible registers are
described in the following sections.
Changes to the register file are not saved in non-volatile memory until a specific command is issued
to the controller. See the description of register
BOARD_COMMAND
in the next sections for more
information on this subject.
In the following sections, the 0x prefix is used to denote a hexadecimal number. The prefix 0x is used
in C and related languages.