1.Nosepiece

2.Viewing Head

3.Eyepiece

4.Objective

5.Specimen Clamp

7.Vernier for Stage Moving Lengthwise 

6.Mechanical Stage

9.Screw for Fixing the Condenser

10.Iris Diaphragm Plate

11.Filter Holder

12.Screw for Condenser Height

14.Knob for Moving Stage Lengthwise(Y) 

15.Knob for Moving Stage Crosswise(X)

23.Fine Focusing Knob

24.Coarse Focusing Knob

25.Knob for Condenser Up or Down 

17.Swtich

18.Plate for Adjusting Brightness

16.Screw for Bulb Changing

8.Screw for Centring the Condenser

Fig 2. The Structure Draft

3. Mechanical tube length: 160mm

4. Conjugated distance between object and image: 195mm

5. Viewing heads and microscope models:

    The viewing heads are used to change the direction of the ray transmitting. Equiped 

different type viewing heads, there are six model microscopes introduced to you for 
different effects.

19.Bulb Case

13.Light Collector

20.Base

21.Rubber Feet

22.Arm

27.Screw for Fixing Viewing Head

26.ABBE Condenser

28.Screw for Stage Height Limitting

75
70
65
55

75
70
65
55

 

Summary of Contents for A11.1303 Series

Page 1: ...www optoecu com 1 15 sale cnoec com A11 1303 Student Biological Microscope Instruction Manual...

Page 2: ...oubleshoot them by yourself according the manual please contact us or our representative in you area 3 Safety Before change a bulb or need to open the base ensure that the microscope has been disconne...

Page 3: ...Focusing System P 5 10 Illumination System P 5 D How to Use and Assemble P 6 E Trouble Shooting P 7 1 Troubles in Operating P 7 2 Troubles in Optical System P 8 3 Troubles in Electric System P 8 F Mai...

Page 4: ...F20X or Huygenian eyepieces as 5X 6X 10X 12 5X 15X 16X The specifications of WF10X are showed as following P 1 a b e c d f Fig 1 The Principle Draft In this microscope the standard outfit of the objec...

Page 5: ...Down 17 Swtich 18 Plate for Adjusting Brightness 16 Screw for Bulb Changing 8 Screw for Centring the Condenser Fig 2 The Structure Draft 3 Mechanical tube length 160mm 4 Conjugated distance between o...

Page 6: ...process software help you to preview measure compare count save and delete Connecting the CCD camera with the TV the micro image will be showed for teaching V type dual observing head 360 rotatable On...

Page 7: ...screen User friendly sophisticated micro image process software help you to preview measure compare count save and delete 3 Insert the CCD camera with the CCD Linker Connecting the CCD camera with th...

Page 8: ...the knob 25 built in rack and pinion mechanical system controls the condenser up or down Usually raise the condenser higher when 100X or 40X objective is used Down the condenser lower when 10X or 4X...

Page 9: ...b D How to use and assemble 1 Unpack the microscope and its parts carefully Check and sort out all parts according to the packing list 2 For the convenience of packaging and delivering the components...

Page 10: ...e 4X and 10X objectives can never come into contacting with your micro slide specimen because of our built in stop The 40X and 100X objectives may occasionally touch the micro slide specimen But becau...

Page 11: ...ld is dark Image moves while focusing The specimen is not caught stably by the clamp The image is yellow Blue filter is not used The viewing field is too dark P 8 Remove the dust and dirt There are du...

Page 12: ...to choose model XSP21 01V or XSP21 01T microscope 1 See Fig 4 and connect the CCD camera with the microscope as following steps 1 Take the plastic dust cover off from the viewing head and screw the v...

Page 13: ...nd its PL pilot lamp is lighting 3 Whether the TV is turned on the mode AV or VIDEO 4 Whether the rod on the right of trinocular head is pushed out 5 Whether the microscope is focused correctly At thi...

Page 14: ...can observe by using common eyepiece at the same time of showing the micro image in the PC screen The electron eyepiece is also used in model XSP21 01M or XSP21 01B microscope See Fig 6 and connect th...

Page 15: ...een as the following ways 1 Turn the plate 19 to make the illuminator darker 2 Turn the plate 10 to make the diameter of the iris diaphragm smaller 3 Rotate the knob 23 to lower the ABBE condenser Whe...

Reviews: