www.optoecu.com 15 / 15 [email protected]
of the condenser and the diameter of the iris diphragm to make the picture clearer.
User-friendly sophisticated micro-image process software help you to preview, measure,
compare, count, save and delete. (See
Appendix B: Digital Camera Head
)
J) XSP21-01DN ditigal microscope:
1) Prepare a PC required:
Hardware
:
USB2.0 Connecting Socket;
CPU: Intel P4; EMS Memory: 256M
Hard Disk: 512M; PC Screen Resolution: 1024*768
Software: win2000(with Mend sp4); or winxp (with Mend sp2) and directx 9.0;
2) Insert the driver CD into your PC and run the installing program as the promating
information (See
Appendix B: Digital Camera Head
);
3) Prepare the microscope for using. Connect it correctly with your PC;
4) Push the rod of the viewing head in completely and adjust the microscope in the best
working state. Then pull the rod out completely. Wait a moment, the micro-picture will be
showed in the PC screen.
Generally, when low-powered objective(4X, or 10X) is used, the picture in the PC
screen will be too bright to observe after the rode of the viewing head is pulled out. You
can adjust the microscopeto get a satisfied picture in the PC screen as the following ways:
1) Turn the plate(19) to make the illuminator darker;
2) Turn the plate(10) to make the diameter of the iris diaphragm smaller;
3) Rotate the knob(23) to lower the ABBE condenser.
When high-powered objective(40X, or 100X) is used, adjust the microscope to get a
satisfied picture as the opposite way:
1) Turn the plate(19) to make the illuminator brighter;
2) Turn the plate(10) to make the diameter of the iris diaphragm larger;
3) Rotate the knob(23) to lift the ABBE condenser higher.
Finally, focus slightly by the fine focusing knob to make the picture clearer. User-friendly
sophisticated micro-image process software help you to preview, measure, compare,
count, save and delete. (See
Appendix B: Digital Camera Head
)
Appendix A: Eyepieces and Objectives for Option
1. Eyepieces for Option:
Wide-field and plano-scope eyepiece
Name
Huygenian eyepiece
Specifications
WF5X, WF6X, WF10X, WF12.5X, WF15X, WF16X, WF20X
5X, 6X, 10X, 12.5X, 15X, 16X
4X, 10X, 20X(S), 40X(S), 60X(S), 100X(S,Oil)
Infinity System Planecope Achromatic Objective
P.12
2. Objectives for Option:
DIN Achromatic Objective
4X, 10X, 20X(S), 40X(S), 60X(S), 100X(S,Oil)
Infinity System Achromatic Objective
Planecope Achromatic Objective
Semi-Planecope Achromatic Objective
4X, 10X, 20X(S), 40X(S), 60X(S), 100X(S,Oil)
4X, 10X, 20X(S), 40X(S), 60X(S), 100X(S,Oil)
4X, 10X, 20X(S), 40X(S), 60X(S), 100X(S,Oil)
Name
Specifications