SRO70 Installation Manual
8
Step 7
Connect the blue tubing from the Optimized Water Outlet on processor to downstream
equipment. Open the feed valve and check for leaks.
v
Place in Service
v
Troubleshooting
Problem
Possible Cause
Resolution
Running out
of water.
Valves in incorrect
operating position
Operating Pressure
reduced
Very cold Feed
Water temperature
Low Feed Water
Pressure
Demand exceeds
system capacity
Ensure the feed water valve and
storage tank valve are open
Pre-Filters need to be replaced
Raise water temp to increase
production or determine if higher
capacity system is required
Install optional Feed Water Pres-
sure Booster Pump
Determine if the demand is
unusual or inconsistent, or resize
system
Poor water
quality.
Membrane failure
Replace AMS-QT10 membrane
Short AMS-
QT10 mem-
brane life.
Poor Feed Water
quality, presence of
iron, silica or non-
calcium carbonate
hardness
Determine Feed Water quality by
obtaining a water quality report
from city water supply utility or
contact your OptiPure dealer
Short Pre-
Filter life
Heavy sediment
loading
Add FXAF01-12 or -12B for
added Pre-Filter protection
Processor
Either Does
Not Shut Off
or Turn On
Auto shutoff valve
not functioning
Replace auto shutoff valve
Optimized Water
to Equipment