OptiPure SRO70 Installation Manual Download Page 2

SRO70 Installation Manual 

Service Contact

For local maintenance and service information, please contact your nearest 

Authorized Service Representative. Service inquiries may be directed to 

technical support at:
  OptiPure div. of Aquion

  101 South Gary Avenue, Suite A

  Roselle, IL 60172 USA
  Phone #:  972.881.9797

  
  E-mail correspondence to: 

 [email protected] 

Environmental Conditions

The SRO70 is certified to operate under the following conditions:

1.   Altitude up to 2000 m.

2.   Ambient temperature of 40-105°F (5 -  40°C).

3.  Max relative humidity 80% at 88°F (31°C).  

4.   Installation category II.

5.   Pollution degree II.

6.   Indoor use only, protect from elements. 

Safety Instructions

1.  Please read and follow these instructions when connecting and using 

the system.

2.  Securely bolt processor to wall before operating.  

3.  Avoid cross-connections and install on cold water supply only.  

4.  Use approved Air-Gaps when connecting to drain lines.

5.  Do not exceed system pressure rating and use water hammer arrestors 

when water hammer is evident.

6.  Turn off Feed-Water supply before filter or membrane cartridge 

replacement.

v

 General Information 

Completed 

SRO70 Installation

2 gal. bladder tank shown

WARNING:

Cancer and Reproductive Harm - 

www.P65Warnings.ca.gov.

Summary of Contents for SRO70

Page 1: ...nual Rev 2 2 SRO70_Simple_Install_v2 2 indd 2018 Procam Controls Inc All Rights Reserved Access manuals spec sheets and additional educational materials for foodservice water treatment at our website...

Page 2: ...relative humidity 80 at 88 F 31 C 4 Installation category II 5 Pollution degree II 6 Indoor use only protect from elements Safety Instructions 1 Please read and follow these instructions when connecti...

Page 3: ...to rain or direct sunlight Feed water connection An adequate flow and pressure of water to the unit is essential for successful operation Drain A drain should be located within 5 ft of the system Dra...

Page 4: ...stalling keep line from the Tank to the equipment as short as possible to minimize pressure loss Avoid loops or kinks in tubing Do not cut tubing with wire crimpers or dikes IMPORTANT PROTECT PROCESSO...

Page 5: ...rs or attach directly to studs Be sure to allow 3 clearance below cartridges for removal Step 2 Route the loose end of 1 4 black tubing from processor to a suitable drain and fasten it at the drain So...

Page 6: ...own in this example Connect the other end to the Feed Water Inlet on processor Step 4 Install the tank valve on the top of the tank Connect a piece of 3 8 blue tubing to tank valve Connect the other e...

Page 7: ...ntil all air is purged from system and product water becomes clear Close the feed valve Step 6 The system includes an optional auxiliary connection This connection provides equipment with water that h...

Page 8: ...increase production or determine if higher capacity system is required Install optional Feed Water Pres sure Booster Pump Determine if the demand is unusual or inconsistent or resize system Poor water...

Reviews: