Version 1.2.8 - 2020-08-03
42
Translation of original operating manual
MT50
GB
MT
5
0_GB
_4.
fm
Set the position of the mechanic built-in limit switch.
Img.5-16: Direction lever
Set the direction lever (X axis) for the table feed to the desired feed direction.
Position the direction lever to the neutral centre position if you switch off the "Feed".
5.13
Moving the cross table forward / back (Y axis)
Loosen the tightening lever.
Engage the crank handle by pushing it towards the clutch.
Turn the handle to the required position for the cross table.
Img.5-17: Moving the cross table to the Y-direction
Make sure to tighten it again in the required position.
Mechanic built-in limit switch
(2x)
Direction lever
Clamping lever
Crank handle