20
Note!
Check local regulations regarding the disposal of de-scaling liquid. Depending on the de-scaling
product used, a special disposal method may be required.
H. Remove soot in combustion chamber.
What you will need: screw driver (+), 10mm wrench, vacuum cleaner, towel and brush.
Steps:
1. Remove all covers and disconnect the H.V cables and fuel pipe from top of the cylinder.
2. Unscrew the 3 bolts on the cylinder cover with 10mm wrench.
3. Open the cylinder cover and clean the steam vessel using a vacuum cleaner, towel, and brush.