13.3. Shock
13.3.1.
Drop Test (without packaging)
No malfunction occurred after the following drop test.
As shown below, drop the scanner from 200 centimeters above the concrete floor
(three times from each of 6 angles).
Figure 25: Product drop test
13.3.2.
Drop Test (with individual packaging)
No malfunction occurred after the following drop test.
Drop the individual package box from 150 centimeters above the concrete floor
(ten times from random angles: on its top, bottom, front, back, left, right, top-left,
top-right, bottom-left, bottom-right)
13.3.3.
Vibration (without packaging)
Swept with 10 Hz to 100 Hz, acceleration 19.6 m/s
2
(2.0G). Added a vibration to
each X, Y and X direction for 30 minutes (1 cycle = 60 minutes) under non-
operational conditions. Observed no abnormality in either appearance or
performance.
13.3.4.
Vibration (individual packaging)
Swept with 10 Hz to 100 Hz, acceleration 19.6 m/s
2
(2.0G). Added a vibration to
each X, Y and X direction for 30 minutes (1 cycle = 60 minutes) with individual
packaging. Observed no abnormality in either appearance or performance.