Opticon
OPR 3001
Specifications Manual
35
13. Durability
13.1. Electrical Noise
No malfunction occurred when sinusoidal electrical noise (10 Hz–100 kHz, < 0.1 Vp-p)
was added to the power supply line.
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
PCS 0.9
Resolution 0.25
mm
Symbology
9-digit Code 39
Quiet Zone
10 mm
N/W Ratio
1:2.5
Distance 100
mm
Angle
α
= 0°
β
= 15°
γ
= 0°
Curvature R
=
∞
Power Supply Voltage
6.0 V (RS-232C) / 5.0 V
(USB and Wedge)
13.2. Static Electricity
Air discharge:
8 kV max (No malfunction)
15 kV max (No destruction)
Contact discharge:
6 kV
Contact discharge at the hook and the screw
Measurement environment:
Use electrostatic testing device compliant with IEC 61000-4-2
Discharge resistance:
330
Ω
Capacitor charging:
150 pF