7.5. Curvature
With 8-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R
≥
15
mm.
With 13-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R
≥
20
mm.
Figure 7: Curvature
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
PCS = 0.9, Resolution = 0.26 mm, Quiet Zone = 10 mm
Distance:
60 mm from the edge of the scanner
Angle: Skew
Angle
β
= +15°
8. Interface
Specifications
8.1. RS-232C Interface Specification
8.1.1.
Settings and Communication
Reading the menu barcodes in section 10.1 can set the RS-232C interface
default.
Parameter [U2]
setting
Baud rate
9600 bps
Start/stop bits
1 bit
Data bits
8 bits
Parity bits
No parity
Handshaking No
handshake
Flow control time out
Indefinitely
Communication settings can be configured by scanning corresponding menu
barcodes.