7.4.3.
Tilt Angle
γ
= ±20°
γ
=
20
°
γ
=
20
°
Figure 6: Tilt angle
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
Distance:
60 mm from the edge of the scanner
Label:
Pitch Angle, Skew Angle, Dead Zone
PCS = 0.9, Resolution = 0.25 mm, Symbology = 9-digit Code-39, Quiet Zone = 10 mm
N/W Ratio = 1:2.5
Tilt Angle
PCS = 0.9, Resolution = 0.26 mm, Symbology = 13-digit JAN, Quiet Zone = 10 mm
Angle:
Pitch Angle:
Skew Angle
β
= +15°, Tilt Angle
γ
= 0°
Tilt Angle:
Pitch Angle
α
= 0°, Skew Angle
β
= +15°
Skew Angle, Dead Zone:
Pitch Angle
α
= 0°, Tilt Angle
γ
= 0°
Curvature: R
=
∞