5-1
Chapter 5 Programming Constants
*** Main Menu***
Operation
U-00: IN=xxx.xV xxx.xAmps
OUT=xxx.xV xxx.xAmps
Use Constant U-00 to monitor the power coming in from the PV array in Volts
and Amps. The second line displays the power going out of the OPTI-Solar
MPPT, it also displays in Volts and Amps.
In most installations there will be a difference between incoming volts and
outgoing volts. This reflects the flexibility of the OPTI-Solar MPPT with respect
to PV array input voltage vs. battery voltage. Incoming and outgoing amps will
also differ because they are the result of dividing watts (a constant) by volts.
U-01: Input Voltage
This screen displays the input voltage value coming from the PV array in Volts.
U-02: Input Current
This screen displays the input current value coming from the PV array in Amps.
U-03:Output Voltage
This screen displays the power going out of the OPTI-Solar MPPT in Volts.
U-04: Output Current
This screen displays the power going out of the OPTI-Solar MPPT in Amps.
U-05: EnergyHarvest Today 1
This screen displays how much the solar energy was harvested “Today” in kWHr
and AHr.
Summary of Contents for SC-160X MPPT
Page 7: ...VII Dimension for SC 50 MPPT Unit mm Fig 1...
Page 8: ...VIII Dimension for SC 80 MPPT Dimension for SC 80X MPPT Unit mm Fig 2...
Page 9: ...IX Dimension for SC 160X MPPT Unit mm Fig 3...
Page 12: ...1 3 Fig 4...
Page 20: ...3 2 3 2 The following is the Initialization Stage Flow Chart OTPI Solar SC 80 MPPT V0 9311...
Page 27: ...3 9 Main Menu Programming Group F Menu Group Constants Constants Edit Data Enter...
Page 28: ...3 10 Main Menu Programming Group O Menu Group Constants Constants Edit Data Enter...
Page 29: ...3 11 Main Menu Data Log Menu Constants Constants Edit Data Enter...