4-6
Data Log
G
G-09
Clear Energy Harvest
Today’s Data
Logged Data
─
Today’s
Data
5-16
NOTE 1 (U-12, U-13, U-14, U-15)
Battery SOC, Battery Current and Battery Amp Hours will only be visible when
terminal BVS (Battery Voltage Sensing) is connected to the battery and will only be
active when using an optional 50mv/500amp external shunt.
Battery Temperature will only be visible when terminal BVS (Battery Voltage Sensing)
is connected to the battery and will only be active when using a Battery Temperature
Sensor (BTS-3).
※
These four constants will only be displayed when the terminal BVS (Battery
Voltage Sensing) is wired to the battery. To show the precise values, an optional
50mv/500amp external shunt is needed for U-12, U-13, U-14 and a Battery
Temperature Sensor is needed for U-15.
NOTE 2 (A-03, A-04)
These two constants are reserved for the authorized distributor or technician to lock
the constants operation.
Lock the constants setting
1.
Finish setting all the programmable constants to the desired values.
2.
Change A-01=Operation Only, factory setting is A-01=Constants Set.
3.
Use UP key to go to A-03 to enter the password 1 (max. 4 digits)
4.
Go to any display of A-xx and press DOWN key and hold it, then press ESC key
at the same time till A-04 constant occurs.
5.
Enter the desired password 2 (max. 4 digits) into A-04. Make sure the password 1
in A-03 must be different from the password 2 in A-04. Finally, press ENTER key
to finish “lock” setting.
Above procedure completes locking the constants setting and no more
programming selection would appear. A-01 would only display Operation only
and would not display Constants Set.
Unlock the constants setting
1.
Enter the password in A-03 to be exactly the same as the one earlier set in A-04
2.
When the password in A-03 matches the one earlier set in A-04, the unlocking is
completed. A-01=Constants Set would appear again for programming.
Summary of Contents for SC-160X MPPT
Page 7: ...VII Dimension for SC 50 MPPT Unit mm Fig 1...
Page 8: ...VIII Dimension for SC 80 MPPT Dimension for SC 80X MPPT Unit mm Fig 2...
Page 9: ...IX Dimension for SC 160X MPPT Unit mm Fig 3...
Page 12: ...1 3 Fig 4...
Page 20: ...3 2 3 2 The following is the Initialization Stage Flow Chart OTPI Solar SC 80 MPPT V0 9311...
Page 27: ...3 9 Main Menu Programming Group F Menu Group Constants Constants Edit Data Enter...
Page 28: ...3 10 Main Menu Programming Group O Menu Group Constants Constants Edit Data Enter...
Page 29: ...3 11 Main Menu Data Log Menu Constants Constants Edit Data Enter...