![opti-solar SC-160X MPPT Installation And Operation Manual Download Page 32](http://html1.mh-extra.com/html/opti-solar/sc-160x-mppt/sc-160x-mppt_installation-and-operation-manual_1641289032.webp)
4-3
Main Menu
Group Constant
LCD Display
Range
Unit
Factory
Setting
Remark
Page
Auxiliary Relay 1
D-01
Set Aux Relay 1 Mode
OFF, ON,
Solar Voltage,
Output Volts,
Battery Volts,
OUT Current,
BATT Current,
Temp.
Battery Temp.
Time
Battery SOC,
Output Volts
OFF
5-9
Aux RY1 ON Condition
See Below
See
Below
See
Below
5-10
When D-01= Solar Voltage
0~150/0~250
0.1V
0
5-10
When D-01=Output Volts
0~64
0.1V
0
5-10
When D-01=Battery Volts
0~64
0.1V
0
5-10
When D-01=OUT Current
0~80/0~160
1A
0
5-10
When D-01=BATT Current
-500~500
1A
0
5-10
When D-01=Temp.
-20~100
1
0
5-10
When D-01=Battery Temp.
-20~100
1
0
5-10
When D-01=Time
00~23 Hr
00~59 Min
1 Min
0
5-10
D-02
When D-01=Battery SOC
0~100
1%
0
5-10
AuxRY1 OFF Condition
See Below
See
Below
See
Below
5-11
When D-01= Solar Voltage
0~150/0~250
0.1V
0
5-11
When D-01=Output Volts
0~64
0.1V
0
5-11
When D-01=Battery Volts
0~64
0.1V
0
5-11
When D-01=OUT Current
0~80/0~160
1A
0
5-11
When D-01=BATT Current
-500~500
1A
0
5-11
When D-01=Temp.
-20~100
1
0
5-11
Programming
D
D-03
When D-01=Battery Temp.
-20~100
1
0
5-11
Summary of Contents for SC-160X MPPT
Page 7: ...VII Dimension for SC 50 MPPT Unit mm Fig 1...
Page 8: ...VIII Dimension for SC 80 MPPT Dimension for SC 80X MPPT Unit mm Fig 2...
Page 9: ...IX Dimension for SC 160X MPPT Unit mm Fig 3...
Page 12: ...1 3 Fig 4...
Page 20: ...3 2 3 2 The following is the Initialization Stage Flow Chart OTPI Solar SC 80 MPPT V0 9311...
Page 27: ...3 9 Main Menu Programming Group F Menu Group Constants Constants Edit Data Enter...
Page 28: ...3 10 Main Menu Programming Group O Menu Group Constants Constants Edit Data Enter...
Page 29: ...3 11 Main Menu Data Log Menu Constants Constants Edit Data Enter...